Catalog

  • You've just added this product to the cart:

    Biochip

    Placeholder

    Biochip

  • You've just added this product to the cart:

    Biochip

    Placeholder

    Biochip

    Acute coronary syndrome (ACS) refers to a range of acute myocardial states, ranging from unstable angina pectoris to acute myocardial infarction (AMI) with or without ST-segment elevation. Diagnosis and risk stratification (from low risk to high risk) are closely linked in ACS.

    Biochemical markers in serum are used as analytical tools for the diagnosis in conjunction with physical examination, clinical history, electrocardiogram and imaging investigations. The Randox Cardiac Array enables the simultaneous determination of four cardiac markers (including late and early markers) from a single sample thus increasing the test result output to facilitate early detection , diagnosis and therapeutic monitoring.

  • You've just added this product to the cart:

    Biochip

    Placeholder

    Biochip

    Acute coronary syndrome (ACS) refers to a range of acute myocardial states, ranging from unstable angina pectoris to acute myocardial infarction (AMI) with or without ST-segment elevation. Diagnosis and risk stratification (from low risk to high risk) are closely linked in ACS.

    Biochemical markers in serum are used as analytical tools for the diagnosis in conjunction with physical examination, clinical history, electrocardiogram and imaging investigations. The Randox Cardiac Array enables the simultaneous determination of four cardiac markers (including late and early markers) from a single sample thus increasing the test result output to facilitate early detection , diagnosis and therapeutic monitoring.

  • You've just added this product to the cart:

    Biochip

    Placeholder

    Biochip

    Tumour markers are proteins found in the blood, tissue or urine that may be directly produced by a tumour or by other tissues in response to the presence of a tumour.

    Prostate cancer is the second most common cause of cancer in men. If it is detected early enough, it has a 90% cure rate. Carcinoembryonic Antigen (CEA), a non-specific cancer antigen produced in response to malignant cells, is measured in addition to total and free Prostate Specific Antigen (PSA). Therefore, testing for CEA simultaneously with PSA provides a more accurate diagnosis of prostate cancer. Randox Tumour PSA Array enables the simultaneous determination of these antigens in a single sample.

  • You've just added this product to the cart:

    BIOFIRE Filmarray Tests

    BIOFIRE Filmarray Tests

    Multiplex PCR system for fast, easy and comprehensive testing

    The FILMARRAY® system is an FDA, CE-IVD, and TGA certified multiplex PCR system that integrates sample preparation, amplification, detection and analysis.

    • Simple: 2 minutes of hands-on time
    • Easy: No precise measuring or pipetting required
    • Fast: Turnaround time of about an hour
    • Comprehensive: Tests for a variety of pathogens that cause respiratory, bloodstream, gastrointestinal infections and meningitis-encephalitis as well antimicrobial resistance genes
  • You've just added this product to the cart:

    Biofire/Filmarray

    Biofire/Filmarray

    Multiplex PCR system for fast, easy and comprehensive testing

    The FILMARRAY® system is an FDA, CE-IVD, and TGA certified multiplex PCR system that integrates sample preparation, amplification, detection and analysis.

    • Simple: 2 minutes of hands-on time
    • Easy: No precise measuring or pipetting required
    • Fast: Turnaround time of about an hour
    • Comprehensive: Tests for a variety of pathogens that cause respiratory, bloodstream, gastrointestinal infections and meningitis-encephalitis as well antimicrobial resistance genes
  • You've just added this product to the cart:

    Biometra Model S2

    Biometra Model S2

    Features

    • Produces a 30 cm x 40 cm gel that fits easily on a standard
      14 in x 17 in X-ray film
    • Integral aluminum plate for even heat distribution to minimise band curvation (“smiling”)
    • Removable lower buffer tray with a separate chamber for collecting the buffer from the upper reservoir, eliminating the need to move the apparatus for buffer disposal
    • Built-in integral clamps hold the gel in place
    • Unique gasket sealing system ensures leak-free operation without grease or notched plates
    • Safety interlock lids
    • Additional combs and apparatus components available separately
  • You've just added this product to the cart:

    Biometra Rotaphor 8 System

    Biometra Rotaphor 8 System

    Features

    • Separation of large DNA molecules (up to 8 Mb = 8,000 kb)
    • Patented electrode rotor allows free electrical field angle
    • Exceptional resolution
    • Optimised protocols for different size ranges
  • You've just added this product to the cart:

    Biometra TGGE and TGGE Maxi System

    Biometra TGGE and TGGE Maxi System

    Features

    Please note: The TGGE systems are discontinued. Accessories are yet available.

    Biometra TGGE System

    • Rapid separation of mixed DNA samples
    • Quick optimisation of new protocols
  • You've just added this product to the cart:

    BIONEXIA BTA

    BIONEXIA BTA

    Non-invasive screening and monitoring of bladder cancer

    The BIONEXIA® BTA rapid test is a useful aid for screening of high-risk populations and monitoring of bladder cancer using urine specimens.

    • Easy test procedure and interpretation
    • No patient discomfort
    • All-inclusive kit
  • You've just added this product to the cart:

    Biosafety Cabinet Bio II Advance

    biosafety cabinet
    biosafety cabinet

    Biosafety Cabinet Bio II Advance

    The smartest innovations in an Advanced Compact Design

    The Bio II Advance has been developed to maximize the convenience, comfort and safety for the user, the sample and the environment whilst minimising the cabinet dimensions. The innovative and elegant design provides the Bio II Advance with a high performance requiring the minimum room space.

    The Bio II Advance achieves the best balance between external dimensions and useful working area in the market. Only 759 mm in width and 1260 mm in height, the Bio II Advance provides a working volume of 340 dm3. Furthermore, the optimized plenum gives the comfort of a large working area with more than enough room in the working chamber for the daily tasks of the user.

    Quite simply, the Bio II Advance has been designed to provide the best Biological Safety Cabinet class II features available while offering practical ergonomics, silent working conditions, easy cleaning, less energy consumption and easy service and maintenance.

    Nowadays most laboratories have low ceilings, and the available space has to be shared with an increasing assortment of equipment. Conscious of this situation, Telstar has re-evaluated Biological Safety Cabinet design, focusing effort on optimization of the core of the cabinet where the filters, fans and electronics are located. The result is compact dimensions and huge improvements in Air Flow Efficiency. The reduced air ways in the plenum combined with microprocessor control, maintains constant airflow during normal filter loading, avoiding wasted energy, reducing cabinet heat and extending filter life.

  • You've just added this product to the cart:

    Biosafety Cabinet BioVanguard

    biosafety cabinet
    biosafety cabinet

    Biosafety Cabinet BioVanguard

    BioVanguard B is a Class II (Type A2) cabinet designed for high risk microbiological and high toxic applications, such as the production of cytotoxic medicines (biosafety levels 1, 2 and 3).

    Telstar BioVanguard Series, our newest range of high quality Class II Biological Safety Cabinets ensures the highest level of protection for operator, product and environment, minimizing hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3.

    This series has been designed according to the highest standards of quality, biological safety, reliability, ergonomics and usability and meets latest customer requirements such as low energy consumption and low sound level.

    Safety standards

    BioVanguard Series is designed and manufactured according to international biosafety standards EN12469: Class II, NSF49: Class II Type A2, JIS K 3800: Class II Type A2. The working area is classified as ISO 14644-1: Class 5, GMP Annex 1: Class A and PIC’s. BioVanguard B is also designed and manufactured according to DIN 12980: Class II.

    Basic principle

    BioVanguard B provides operator protection by inflow, product protection by HEPA-filtered laminar down flow in the working area (30% exhaust; 70% recirculation) and environmental protection by HEPA-filtered exhaust air.

    BioVanguard B is equipped with additional V-shaped HEPA filters underneath the work surface, which filter the inflow air and keep the internal construction of the cabinet free of contamination and therefore ensures the topmost safety for high risk applications.

  • You've just added this product to the cart:

    Biosafety Cabinet BioVanguard Class II

    biosafety cabinet
    biosafety cabinet

    Biosafety Cabinet BioVanguard Class II

    BioVanguard is a Class II (Type A2) cabinet designed for microbiological research with biological agents (e.g. bacteria, viruses, etc) and allergens (biosafety levels 1, 2 and 3).

    Telstar BioVanguard Series, our newest range of high quality Class II Biological Safety Cabinets ensures the highest level of protection for operator, product and environment, minimizing hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3.

    This series has been designed according to the highest standards of quality, biological safety, reliability, ergonomics and usability and meets latest customer requirements such as low energy consumption and low sound level.

    Safety standards

    BioVanguard Series is designed and manufactured according to international biosafety standards EN12469: Class II, NSF49: Class II Type A2, JIS K 3800: Class II Type A2. The working area is classified as ISO 14644-1: Class 5, GMP Annex 1: Class A and PIC’s.

    Basic principle

    BioVanguard provides operator protection by inflow, product protection by HEPA-filtered laminar down flow in the working area (30% exhaust; 70% recirculation) and environmental protection by HEPA-filtered exhaust air.

  • You've just added this product to the cart:

    Biosafety Cabinet EF/B2

    biosafety cabinet
    biosafety cabinet

    Biosafety Cabinet EF/B2

    Telstar EF/B Biological Safety Cabinets Class II, Type B2 with 100% exhausted and 0% recirculated.

    Type B2 Biosafety Cabinets according to NSF 49 provide personnel, product and environmental protection from hazardous microorganisms that require Biosafety Level BSL-1, BSL-2 and BSL-3. These biological safety cabinets are designed to be hard ducted to the outside. During operation, room air passes into the top of the cabinet and through a supply HEPA filter to provide a laminar air flow into the working chamber. Contaminated air is also drawn into the exhaust HEPA-14 filter located down the working area before be exhausted. A dedicated exhaust system and remote blower exhaust the 100% of the filtered air from the cabinet. Since none of the air is recirculated, these biosafety cabinets are appropriated to be used when the user is working with toxic and volatile chemical substances.

  • You've just added this product to the cart:

    Biosafety Cabinet EuroFlow - Type EF

    biosafety cabinet
    biosafety cabinet

    Biosafety Cabinet EuroFlow – Type EF

    Type EF of EuroFlow Series is a Class II (Type A2) cabinet designed for microbiological research with biological agents (e.g. bacteria, viruses, etc) and allergens (biosafety levels 1, 2 and 3).

    Telstar Clean Air EuroFlow Series, our top range of high quality Class II Biological Safety Cabinets ensures the highest level of protection for operator, product and environment, minimizing hazards inherent to working with agents assigned to biosafety levels 1, 2 and 3.

    This series has been designed according to the highest standards of quality, biological safety, reliability,

    ergonomics and usability.

    Safety standards

    EuroFlow Series is designed and manufactured according to international biosafety standards EN12469 (Class II), NSF49 (Class II Type A2) and JIS K 3800 (Class II Type A2). EuroFlow Series is fully certified by TüV Nord in accordance with EN 12469. The working area is classified as ISO 14644-1 (Class 5) and GMP Annex 1 (Class A).

    Basic principle