-
qTOWER³ 84
Enhance Your Throughput – A New Standard for Speed and Precision in High-throughput qPCR
With steadily growing sample volumes and new options for molecular biology experiments, the requirements for quantitative real-time PCR are changing. The transition to the multiwell format with 384 samples opens up new application areas in gene expression, mutation analysis, and diagnostics.
-
qTOWER³ auto
Automation Made Easy
In addition to the externally accessible sample tray, plate handling is also automated in qTOWER³ auto. The 96 well microplate is positioned precisely within the block and, following amplification, is unloaded just as efficiently. Visualizing a continuous workflow is easy and reliable. The concept of automated real-time PCR accommodates a variety of integration strategies. The length of the cable for the decoupled electronics module is up to 10 m, making it easy to integrate from a decentralized location. The size of the rest of the instrument is then only just 27.5 cm x 46 cm x 31 cm (W x H x D), and the height of the sample tray (minimum = 12 cm) is easy to adjust. The cycler unit can be positioned next to the liquid handling system to save space, in which case the plate is loaded using an external robotic arm (as used in the CyBi®-Carry) or by directly connecting the sample tray to the liquid handling station.
-
QuEChERS Dispersive Solid Phase Extraction
QuEChERS Dispersive Solid Phase Extraction
Dispersive solid phase extraction (d-SPE) analysis is a simple and straightforward sample preparation technique suitable for a wide variety of food and agricultural products. One specific method which has become popular is the QuEChERS technique which was created to facilitate the rapid screening of large numbers of food and agricultural samples for pesticide residues. Waters DisQuE d-SPE products include conveniently-packaged centrifuge tubes and foil pouches containing pre-weighed sorbents and buffers for use with both the Association of Analytical Communities (AOAC) and European Committee for Standardization (CEN) QuEChERS methods. Waters QuEChERS kits make sample prep quick and easy for multi-residue analysis in food and agricultural products.
Compared to traditional sample preparation techniques, DisQuE solutions offer:
- Decreased time spent on sample preparation
- Efficient and cost effective sample preparation
- Reliable, high-quality product in a convenient format
-
Reagents
Achieve Optimum Results
Your choice of mobile phases, solvents and additives can have a significant impact on your chromatographic and spectrophotometric results. That is why Waters provides standards kits and ready-to-use reagents that are prepared using the highest quality materials for all your critical analyses.
- Optimized for use with LC and LCMS instrumentation
- Integral part of many application solutions that include columns and standards
-
Sartorius
Lab Weighing with Sartorius
Balances and Scales for the Laboratory
Laboratory balances are defined by high levels of accuracy and precision in analytical testing and quantitative analysis. Used in a variety of applications, they are divided into five subcategories according to their read
-
Sartorius Vacuum Manifold
Reusable stainless steel funnels for microbial enumeration and particle counting. Specially designed for use in microbiological quality assurance, these three filter holders differ only in their capacity. The reusable funnels feature a special locking clamp that simplifies the positioning and removal of the membrane filter, ensuring secure lock-down. For traceability, each filter funnel has an individual serial number.
-
ScanDrop²
Efficient, Robust Spectrophotometer
The ScanDrop2 is a versatile, robust instrument that is user friendly without sacrificing measurement reliability. Optimized for the UV/Vis range, its symmetrical Czerny-Turner design with a linear CCD detector ensures excellent stability and reproducible results while offering a high level of resolution (≥ 1.2 nm).
Its long-lasting xenon flash lamp, which, unlike other systems,
requires no warm-up phase, means that the ScanDrop2 is immediately ready-to-use. At 109 flashes (approx. 100,000 hours), the product life of this lamp exceeds that of conventional light sources by orders of magnitude, delivering fast results and measurements that only takes 4 sec per spectrum. The heart of the ScanDrop2 is the polychromator system, which uses no moving components. The settings are permanent, and the system is fixed in place and resistant to external influencing factors, eliminating the need for calibration. -
SLIDEX – Latex Agglutination
High performance identification latex tests
- High specificity
- Extremely rapid
- Ready-to-use
- Home
- Products
- Sectors
- Clinical Laboratories
- IMAGING SECTORS
- Industry & Research Labs
- Test Parameters
- Partners
- Biomerieux
- Greiner
- VWR
- Aptaca
- Biolife
- Canon Medical Systems
- Waters
- Honeywell
- Gesan
- Isolab
- Randox
- Macopharma
- Mediwiss
- Polatom
- Kima
- Sigma Centrifugen
- Mast GRP
- Tecna
- CTK
- Hain Lifescience
- Vicam
- DNA Technology
- Dirui
- Elitech
- Sifin
- Microgen
- Chromsystems
- Barchemicals
- Analytik Jena
- Instrumentation Laboratory
- Bag Health
- Hach Lange
- Ahlstrom
- Fast Track Diagnostics
- Wako Chemicals
- Xylem
- Memmert
- Alkaloid
- Brand
- Eppendorf
- Binder
- About Us
- Blog
- Contact Us
















